DeviceModel
<StructureDefinition xmlns="http://hl7.org/fhir">
<id value="cimi-entity-Device-model"/>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml">
<p><b>SW Device Logical Model</b></p>
<p>A specific durable physical device used in diagnosis or treatment. The value is the coding for a type of device, for example, a CPAP machine. The same device might be used on multiple patients.</p>
</div>
</text>
<url
value="http://hl7.org/fhir/us/sw/StructureDefinition/cimi-entity-Device-model"/>
<identifier>
<system value="http://hl7.org/fhir/us/sw"/>
<value value="cimi.entity.Device"/>
</identifier>
<version value="1.0.0"/>
<name value="DeviceModel"/>
<title value="SW Device Logical Model"/>
<status value="draft"/>
<date value="2018-08-17T00:00:00-04:00"/>
<publisher
value="HL7 Patient Care and Clinical Information Modeling Initiative Work Groups"/>
<contact>
<telecom>
<system value="url"/>
<value value="http://standardhealthrecord.org"/>
</telecom>
</contact>
<description
value="A specific durable physical device used in diagnosis or treatment. The value is the coding for a type of device, for example, a CPAP machine. The same device might be used on multiple patients."/>
<kind value="logical"/>
<abstract value="false"/>
<type value="cimi-entity-Device-model"/>
<baseDefinition value="http://hl7.org/fhir/StructureDefinition/Element"/>
<derivation value="specialization"/>
<snapshot>
<element id="cimi-entity-Device-model">
<path value="cimi-entity-Device-model"/>
<definition
value="A specific durable physical device used in diagnosis or treatment. The value is the coding for a type of device, for example, a CPAP machine. The same device might be used on multiple patients."/>
<min value="0"/>
<max value="*"/>
<base>
<path value="cimi-entity-Device-model"/>
<min value="0"/>
<max value="*"/>
</base>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
<element id="cimi-entity-Device-model.type">
<path value="cimi-entity-Device-model.type"/>
<code>
<system value="http://ncimeta.nci.nih.gov"/>
<code value="C0332307"/>
</code>
<short
value="The most specific code (lowest level term) describing the kind or sort of thing being represented."/>
<definition
value="The most specific code (lowest level term) describing the kind or sort of thing being represented."/>
<min value="1"/>
<max value="1"/>
<base>
<path value="cimi-entity-Device-model.type"/>
<min value="1"/>
<max value="1"/>
</base>
<type>
<code value="Coding"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
<binding>
<strength value="required"/>
<valueSetReference>
<reference
value="http://hl7.org/fhir/us/sw/ValueSet/cimi-entity-DeviceVS"/>
</valueSetReference>
</binding>
</element>
<element id="cimi-entity-Device-model.deviceUdi">
<path value="cimi-entity-Device-model.deviceUdi"/>
<short
value="Unique Device Identifier (UDI) Barcode string number for a device, assigned by the organization using the device."/>
<definition
value="Unique Device Identifier (UDI) Barcode string number for a device, assigned by the organization using the device."/>
<min value="0"/>
<max value="*"/>
<base>
<path value="cimi-entity-Device-model.deviceUdi"/>
<min value="0"/>
<max value="*"/>
</base>
<type>
<code value="string"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
<element id="cimi-entity-Device-model.vendorModelNumber">
<path value="cimi-entity-Device-model.vendorModelNumber"/>
<short
value="The model number of the device, assigned by the manufacturer or vendor."/>
<definition
value="The model number of the device, assigned by the manufacturer or vendor."/>
<min value="0"/>
<max value="1"/>
<base>
<path value="cimi-entity-Device-model.vendorModelNumber"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="string"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
<element id="cimi-entity-Device-model.manufacturerName">
<path value="cimi-entity-Device-model.manufacturerName"/>
<short value="The name of the company who produce the device."/>
<definition value="The name of the company who produce the device."/>
<min value="0"/>
<max value="1"/>
<base>
<path value="cimi-entity-Device-model.manufacturerName"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="string"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
<element id="cimi-entity-Device-model.manufactureDate">
<path value="cimi-entity-Device-model.manufactureDate"/>
<short value="When the item (medication, device, etc.) was produced."/>
<definition value="When the item (medication, device, etc.) was produced."/>
<min value="0"/>
<max value="1"/>
<base>
<path value="cimi-entity-Device-model.manufactureDate"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="dateTime"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
<element id="cimi-entity-Device-model.expirationDate">
<path value="cimi-entity-Device-model.expirationDate"/>
<short value="When the item (medication, device, etc.) will expire."/>
<definition value="When the item (medication, device, etc.) will expire."/>
<min value="0"/>
<max value="1"/>
<base>
<path value="cimi-entity-Device-model.expirationDate"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="dateTime"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
<element id="cimi-entity-Device-model.version">
<path value="cimi-entity-Device-model.version"/>
<code>
<system value="http://ncimeta.nci.nih.gov"/>
<code value="C0333052"/>
</code>
<short
value="A number or code associated with the product that identifies a particular release iteration."/>
<definition
value="A number or code associated with the product that identifies a particular release iteration."/>
<min value="0"/>
<max value="1"/>
<base>
<path value="cimi-entity-Device-model.version"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="string"/>
</type>
<type>
<code value="id"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
<element id="cimi-entity-Device-model.url">
<path value="cimi-entity-Device-model.url"/>
<short value="A unique URL on which the device may be contacted directly."/>
<definition
value="A unique URL on which the device may be contacted directly."/>
<min value="0"/>
<max value="1"/>
<base>
<path value="cimi-entity-Device-model.url"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="uri"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
</snapshot>
<differential>
<element id="cimi-entity-Device-model">
<path value="cimi-entity-Device-model"/>
<definition
value="A specific durable physical device used in diagnosis or treatment. The value is the coding for a type of device, for example, a CPAP machine. The same device might be used on multiple patients."/>
<min value="0"/>
<max value="*"/>
<base>
<path value="cimi-entity-Device-model"/>
<min value="0"/>
<max value="*"/>
</base>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
<element id="cimi-entity-Device-model.type">
<path value="cimi-entity-Device-model.type"/>
<code>
<system value="http://ncimeta.nci.nih.gov"/>
<code value="C0332307"/>
</code>
<short
value="The most specific code (lowest level term) describing the kind or sort of thing being represented."/>
<definition
value="The most specific code (lowest level term) describing the kind or sort of thing being represented."/>
<min value="1"/>
<max value="1"/>
<base>
<path value="cimi-entity-Device-model.type"/>
<min value="1"/>
<max value="1"/>
</base>
<type>
<code value="Coding"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
<binding>
<strength value="required"/>
<valueSetReference>
<reference
value="http://hl7.org/fhir/us/sw/ValueSet/cimi-entity-DeviceVS"/>
</valueSetReference>
</binding>
</element>
<element id="cimi-entity-Device-model.deviceUdi">
<path value="cimi-entity-Device-model.deviceUdi"/>
<short
value="Unique Device Identifier (UDI) Barcode string number for a device, assigned by the organization using the device."/>
<definition
value="Unique Device Identifier (UDI) Barcode string number for a device, assigned by the organization using the device."/>
<min value="0"/>
<max value="*"/>
<base>
<path value="cimi-entity-Device-model.deviceUdi"/>
<min value="0"/>
<max value="*"/>
</base>
<type>
<code value="string"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
<element id="cimi-entity-Device-model.vendorModelNumber">
<path value="cimi-entity-Device-model.vendorModelNumber"/>
<short
value="The model number of the device, assigned by the manufacturer or vendor."/>
<definition
value="The model number of the device, assigned by the manufacturer or vendor."/>
<min value="0"/>
<max value="1"/>
<base>
<path value="cimi-entity-Device-model.vendorModelNumber"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="string"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
<element id="cimi-entity-Device-model.manufacturerName">
<path value="cimi-entity-Device-model.manufacturerName"/>
<short value="The name of the company who produce the device."/>
<definition value="The name of the company who produce the device."/>
<min value="0"/>
<max value="1"/>
<base>
<path value="cimi-entity-Device-model.manufacturerName"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="string"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
<element id="cimi-entity-Device-model.manufactureDate">
<path value="cimi-entity-Device-model.manufactureDate"/>
<short value="When the item (medication, device, etc.) was produced."/>
<definition value="When the item (medication, device, etc.) was produced."/>
<min value="0"/>
<max value="1"/>
<base>
<path value="cimi-entity-Device-model.manufactureDate"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="dateTime"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
<element id="cimi-entity-Device-model.expirationDate">
<path value="cimi-entity-Device-model.expirationDate"/>
<short value="When the item (medication, device, etc.) will expire."/>
<definition value="When the item (medication, device, etc.) will expire."/>
<min value="0"/>
<max value="1"/>
<base>
<path value="cimi-entity-Device-model.expirationDate"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="dateTime"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
<element id="cimi-entity-Device-model.version">
<path value="cimi-entity-Device-model.version"/>
<code>
<system value="http://ncimeta.nci.nih.gov"/>
<code value="C0333052"/>
</code>
<short
value="A number or code associated with the product that identifies a particular release iteration."/>
<definition
value="A number or code associated with the product that identifies a particular release iteration."/>
<min value="0"/>
<max value="1"/>
<base>
<path value="cimi-entity-Device-model.version"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="string"/>
</type>
<type>
<code value="id"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
<element id="cimi-entity-Device-model.url">
<path value="cimi-entity-Device-model.url"/>
<short value="A unique URL on which the device may be contacted directly."/>
<definition
value="A unique URL on which the device may be contacted directly."/>
<min value="0"/>
<max value="1"/>
<base>
<path value="cimi-entity-Device-model.url"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="uri"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
</differential>
</StructureDefinition>