WoundPeriwoundDescriptionModel
<StructureDefinition xmlns="http://hl7.org/fhir">
<id value="sw-WoundPeriwoundDescription-model"/>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml">
<p><b>SW WoundPeriwoundDescription Logical Model</b></p>
<p>A description of the skin around the wound (periwound). Color, induration, warmth and edema should be assessed. Redness of the surrounding skin can be indicative of unrelieved pressure. Irritation of the surrounding skin can result from exposure to feces or urine, a reaction to the dressing or tape, or inappropriate removal of dressing or tape. Redness, tenderness, warmth and swelling are classical clinical signs of infection. [Reference: Brown, P., 2009]</p>
</div>
</text>
<url
value="http://hl7.org/fhir/us/sw/StructureDefinition/sw-WoundPeriwoundDescription-model"/>
<identifier>
<system value="http://hl7.org/fhir/us/sw"/>
<value value="sw.WoundPeriwoundDescription"/>
</identifier>
<version value="1.0.0"/>
<name value="WoundPeriwoundDescriptionModel"/>
<title value="SW WoundPeriwoundDescription Logical Model"/>
<status value="draft"/>
<date value="2018-08-17T00:00:00-04:00"/>
<publisher
value="HL7 Patient Care and Clinical Information Modeling Initiative Work Groups"/>
<contact>
<telecom>
<system value="url"/>
<value value="http://standardhealthrecord.org"/>
</telecom>
</contact>
<description
value="A description of the skin around the wound (periwound). Color, induration, warmth and edema should be assessed. Redness of the surrounding skin can be indicative of unrelieved pressure. Irritation of the surrounding skin can result from exposure to feces or urine, a reaction to the dressing or tape, or inappropriate removal of dressing or tape. Redness, tenderness, warmth and swelling are classical clinical signs of infection. [Reference: Brown, P., 2009]"/>
<keyword>
<system value="http://loinc.org"/>
<code value="72301-5"/>
</keyword>
<kind value="logical"/>
<abstract value="false"/>
<type value="sw-WoundPeriwoundDescription-model"/>
<baseDefinition value="http://hl7.org/fhir/StructureDefinition/Element"/>
<derivation value="specialization"/>
<snapshot>
<element id="sw-WoundPeriwoundDescription-model">
<path value="sw-WoundPeriwoundDescription-model"/>
<definition
value="A description of the skin around the wound (periwound). Color, induration, warmth and edema should be assessed. Redness of the surrounding skin can be indicative of unrelieved pressure. Irritation of the surrounding skin can result from exposure to feces or urine, a reaction to the dressing or tape, or inappropriate removal of dressing or tape. Redness, tenderness, warmth and swelling are classical clinical signs of infection. [Reference: Brown, P., 2009]"/>
<min value="0"/>
<max value="*"/>
<base>
<path value="sw-WoundPeriwoundDescription-model"/>
<min value="0"/>
<max value="*"/>
</base>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
<element id="sw-WoundPeriwoundDescription-model.value">
<path value="sw-WoundPeriwoundDescription-model.value"/>
<short
value="Code representing a description of the skin around the wound (periwound). Color, induration, warmth and edema should be assessed. Redness of the surrounding skin can be indicative of unrelieved pressure. Irritation of the surrounding skin can result from exposure to feces or urine, a reaction to the dressing or tape, or inappropriate removal of dressing or tape. Redness, tenderness, warmth and swelling are classical clinical signs of infection. [Reference: Brown, P., 2009]"/>
<definition
value="Code representing a description of the skin around the wound (periwound). Color, induration, warmth and edema should be assessed. Redness of the surrounding skin can be indicative of unrelieved pressure. Irritation of the surrounding skin can result from exposure to feces or urine, a reaction to the dressing or tape, or inappropriate removal of dressing or tape. Redness, tenderness, warmth and swelling are classical clinical signs of infection. [Reference: Brown, P., 2009]"/>
<min value="1"/>
<max value="1"/>
<base>
<path value="sw-WoundPeriwoundDescription-model.value"/>
<min value="1"/>
<max value="1"/>
</base>
<type>
<code value="Coding"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
<binding>
<strength value="required"/>
<valueSetReference>
<reference
value="https://vsac.nlm.nih.gov/valueset/2.16.840.1.113762.1.4.1181.2/expansion"/>
</valueSetReference>
</binding>
</element>
<element id="sw-WoundPeriwoundDescription-model.topicCode">
<path value="sw-WoundPeriwoundDescription-model.topicCode"/>
<short
value="The concept representing the finding or action that is the topic of the statement."/>
<definition
value="The concept representing the finding or action that is the topic of the statement.
For action topics, the TopicCode represents the action being described. For findings, the TopicCode represents the 'question' or property being investigated. For evaluation result findings, the TopicCode contains a concept for an observable entity, such as systolic blood pressure. For assertion findings, the TopicCode contains a code representing the condition, allergy, or other item being asserted. In all cases, the TopicCode describes the topic of the action or the finding."/>
<min value="0"/>
<max value="1"/>
<base>
<path value="sw-WoundPeriwoundDescription-model.topicCode"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="Coding"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
<element id="sw-WoundPeriwoundDescription-model.exceptionValue">
<path value="sw-WoundPeriwoundDescription-model.exceptionValue"/>
<short
value="Reason that a value associated with a test or other finding is missing."/>
<definition
value="Reason that a value associated with a test or other finding is missing."/>
<min value="0"/>
<max value="1"/>
<base>
<path value="sw-WoundPeriwoundDescription-model.exceptionValue"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="Coding"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
<binding>
<strength value="extensible"/>
<valueSetReference>
<reference value="http://hl7.org/fhir/ValueSet/data-absent-reason"/>
</valueSetReference>
</binding>
</element>
<element id="sw-WoundPeriwoundDescription-model.interpretation">
<path value="sw-WoundPeriwoundDescription-model.interpretation"/>
<code>
<system value="http://ncimeta.nci.nih.gov"/>
<code value="C0420833"/>
</code>
<short
value="A clinical interpretation of a finding (applies to both assertions and observation)."/>
<definition
value="A clinical interpretation of a finding (applies to both assertions and observation)."/>
<min value="0"/>
<max value="1"/>
<base>
<path value="sw-WoundPeriwoundDescription-model.interpretation"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="Coding"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
<binding>
<strength value="extensible"/>
<valueSetReference>
<reference
value="http://hl7.org/fhir/ValueSet/observation-interpretation"/>
</valueSetReference>
</binding>
</element>
<element id="sw-WoundPeriwoundDescription-model.referenceRange">
<path value="sw-WoundPeriwoundDescription-model.referenceRange"/>
<code>
<system value="http://ncimeta.nci.nih.gov"/>
<code value="C0883335"/>
</code>
<short value="The usual or acceptable range for a test result."/>
<definition value="The usual or acceptable range for a test result."/>
<min value="0"/>
<max value="0"/>
<base>
<path value="sw-WoundPeriwoundDescription-model.referenceRange"/>
<min value="0"/>
<max value="0"/>
</base>
<type>
<code
value="http://hl7.org/fhir/us/sw/StructureDefinition/cimi-statement-ReferenceRange-model"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
</snapshot>
<differential>
<element id="sw-WoundPeriwoundDescription-model">
<path value="sw-WoundPeriwoundDescription-model"/>
<definition
value="A description of the skin around the wound (periwound). Color, induration, warmth and edema should be assessed. Redness of the surrounding skin can be indicative of unrelieved pressure. Irritation of the surrounding skin can result from exposure to feces or urine, a reaction to the dressing or tape, or inappropriate removal of dressing or tape. Redness, tenderness, warmth and swelling are classical clinical signs of infection. [Reference: Brown, P., 2009]"/>
<min value="0"/>
<max value="*"/>
<base>
<path value="sw-WoundPeriwoundDescription-model"/>
<min value="0"/>
<max value="*"/>
</base>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
<element id="sw-WoundPeriwoundDescription-model.value">
<path value="sw-WoundPeriwoundDescription-model.value"/>
<short
value="Code representing a description of the skin around the wound (periwound). Color, induration, warmth and edema should be assessed. Redness of the surrounding skin can be indicative of unrelieved pressure. Irritation of the surrounding skin can result from exposure to feces or urine, a reaction to the dressing or tape, or inappropriate removal of dressing or tape. Redness, tenderness, warmth and swelling are classical clinical signs of infection. [Reference: Brown, P., 2009]"/>
<definition
value="Code representing a description of the skin around the wound (periwound). Color, induration, warmth and edema should be assessed. Redness of the surrounding skin can be indicative of unrelieved pressure. Irritation of the surrounding skin can result from exposure to feces or urine, a reaction to the dressing or tape, or inappropriate removal of dressing or tape. Redness, tenderness, warmth and swelling are classical clinical signs of infection. [Reference: Brown, P., 2009]"/>
<min value="1"/>
<max value="1"/>
<base>
<path value="sw-WoundPeriwoundDescription-model.value"/>
<min value="1"/>
<max value="1"/>
</base>
<type>
<code value="Coding"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
<binding>
<strength value="required"/>
<valueSetReference>
<reference
value="https://vsac.nlm.nih.gov/valueset/2.16.840.1.113762.1.4.1181.2/expansion"/>
</valueSetReference>
</binding>
</element>
<element id="sw-WoundPeriwoundDescription-model.topicCode">
<path value="sw-WoundPeriwoundDescription-model.topicCode"/>
<short
value="The concept representing the finding or action that is the topic of the statement."/>
<definition
value="The concept representing the finding or action that is the topic of the statement.
For action topics, the TopicCode represents the action being described. For findings, the TopicCode represents the 'question' or property being investigated. For evaluation result findings, the TopicCode contains a concept for an observable entity, such as systolic blood pressure. For assertion findings, the TopicCode contains a code representing the condition, allergy, or other item being asserted. In all cases, the TopicCode describes the topic of the action or the finding."/>
<min value="0"/>
<max value="1"/>
<base>
<path value="sw-WoundPeriwoundDescription-model.topicCode"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="Coding"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
<element id="sw-WoundPeriwoundDescription-model.exceptionValue">
<path value="sw-WoundPeriwoundDescription-model.exceptionValue"/>
<short
value="Reason that a value associated with a test or other finding is missing."/>
<definition
value="Reason that a value associated with a test or other finding is missing."/>
<min value="0"/>
<max value="1"/>
<base>
<path value="sw-WoundPeriwoundDescription-model.exceptionValue"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="Coding"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
<binding>
<strength value="extensible"/>
<valueSetReference>
<reference value="http://hl7.org/fhir/ValueSet/data-absent-reason"/>
</valueSetReference>
</binding>
</element>
<element id="sw-WoundPeriwoundDescription-model.interpretation">
<path value="sw-WoundPeriwoundDescription-model.interpretation"/>
<code>
<system value="http://ncimeta.nci.nih.gov"/>
<code value="C0420833"/>
</code>
<short
value="A clinical interpretation of a finding (applies to both assertions and observation)."/>
<definition
value="A clinical interpretation of a finding (applies to both assertions and observation)."/>
<min value="0"/>
<max value="1"/>
<base>
<path value="sw-WoundPeriwoundDescription-model.interpretation"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="Coding"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
<binding>
<strength value="extensible"/>
<valueSetReference>
<reference
value="http://hl7.org/fhir/ValueSet/observation-interpretation"/>
</valueSetReference>
</binding>
</element>
<element id="sw-WoundPeriwoundDescription-model.referenceRange">
<path value="sw-WoundPeriwoundDescription-model.referenceRange"/>
<code>
<system value="http://ncimeta.nci.nih.gov"/>
<code value="C0883335"/>
</code>
<short value="The usual or acceptable range for a test result."/>
<definition value="The usual or acceptable range for a test result."/>
<min value="0"/>
<max value="0"/>
<base>
<path value="sw-WoundPeriwoundDescription-model.referenceRange"/>
<min value="0"/>
<max value="0"/>
</base>
<type>
<code
value="http://hl7.org/fhir/us/sw/StructureDefinition/cimi-statement-ReferenceRange-model"/>
</type>
<mustSupport value="false"/>
<isModifier value="false"/>
<isSummary value="false"/>
</element>
</differential>
</StructureDefinition>