MITRE's 'Mini-CIMI' FHIR Profile: Skin and Wound Assessment, Release 1 (For Comment)

WoundTrendModel

 

The official URL for this logical model is:

http://hl7.org/fhir/us/sw/StructureDefinition/sw-WoundTrend-model

Whether a condition is improving, worsening, stable, or resolved.

This logical model was published on Fri Aug 17 00:00:00 EDT 2018 as a draft by HL7 Patient Care and Clinical Information Modeling Initiative Work Groups.

View the corresponding WoundTrendProfile profile.

NameFlagsCard.TypeDescription & Constraintsdoco
.. sw-WoundTrend-model 0..*
... findingStatus 1..1codeIndicates whether the finding is preliminary, amended, final, etc.
Binding: ObservationStatus (required)
... relevantTime 0..1dateTime, TimePeriodModelThe time or time period that the statement addresses.
... findingMethod 0..1CodingThe method used to determine the finding.
... subject 1..1WoundModelThe person, place, event, condition, other statement that this statement addresses or belongs to.
... observableCode 1..1CodingA code describing the aspect or property of the subject being observed or measured. The ObservableCode is the 'question code' that pairs to the 'answer' contained in the ResultValue.
.... extension 0..*ExtensionAdditional Content defined by implementations
Slice: Unordered, Open by value:url
.... system Σ1..1uriIdentity of the terminology system
Fixed Value: http://loinc.org
.... version Σ0..1stringVersion of the system - if relevant
.... code Σ1..1codeSymbol in syntax defined by the system
Fixed Value: 89253-9
.... display Σ0..1stringRepresentation defined by the system
.... userSelected Σ0..1booleanIf this coding was chosen directly by the user
... resultValue 0..1CodingThe finding itself, such as the blood pressure value recorded.
Binding: LOINC Answer List LL4938-8 (preferred)
... qualifier 0..*CodingA condition or circumstance associated with an observation that affects the interpretation of the result value.

doco Documentation for this format

Downloads: StructureDefinition: (XML, JSON, TTL)

 

Terminology Bindings

PathNameConformanceValueSet
sw-WoundTrend-model.findingStatusObservationStatusrequiredObservationStatus
sw-WoundTrend-model.resultValueLOINC LL4938-8preferredLOINC LL4938-8